Flexscan FS200 OTDR

with FleXpress™ and Linkmap®

AFL’s FlexScan FS200 OTDR is an all-in-one solution for detecting, identifying, locating, and resolving single-mode optical network issues. It is designed for both novice and expert technicians working in a range of environments, from FTTH PON to point-to-point networks. It applies industry-standard or user-set pass/fail criteria and displays results using LinkMap colour-coded icons to show the health of the network. FlexScans automate test setup, shorten test time, and simplify results interpretation improving efficiency and reducing costs.

Applications:

  • PON or point-to-point network verification or troubleshooting
  • OTDR testing plus insertion loss and power measurements
  • Locate faults exceeding industry or user pass/fail thresholds
  • Visually pinpoint location of macro-bends or breaks

© All images remain the property of their respective manufacturers and are used with permission.
MODEL: FS200-XXX -60 -100 -300 -303 -304
OTDR
Emitter Type Laser
Safety Class b Class I
Fibre Type Single-mode
Wavelengths (nm) 1650 1310/1550 1310/1550 1310/1550/1625
1310/1550/1650
Center Tolerance c 1310/1550/1650: ±20 nm; 1625 +30/-5 nm
Dynamic Range d (dB) 37 32/30 37/35 37/35/37 37/35/37
Event Dead Zone e (m) 0.8 0.8 0.8 0.8 0.8
Atten. Dead Zone f (m) 3.5 3.6 3.5 3.5 3.5
PON Dead Zone g (m) 30 N/A 25/25 25/25/40 25/25/40
Max Split Ratio 1:64 (FS200-60/30x only); N/A (FS200-100)
Pulse Widths 3, 5, 10, 20, 30, 50, 100, 200, 300, 500 ns;
1, 2, 3, 10 µs; 20 µs (FS200-300/303/304 only)
Range Settings 250 m to 240 km
Data Points Up to 300,000 (Expert mode .SOR file)
Data Spacing 5 cm to 16 m
Index of Refraction 1.3000 to 1.7000
Distance Uncertainty ±(1 + 0.003% x distance + data point spacing) m
Linearity (dB/dB) ±0.05
Trace File Format Telcordia SR-4731 Issue 2 compatible .SOR
Trace Storage Medium 4 GB internal memory (> 5000 traces typical); External USB memory stick
Data Transfer to PC USB cable or Bluetooth® (option)
OTDR Modes SmartAuto, Expert, Real-time
FleXpress Fast Test FS200-300/303/304
Display Modes LinkMap Summary, LinkMap Events, Trace
Refresh Rate Up to 4 Hz (Real-time mode)
Live Fiber Protection No OTDR damage with input power ≤ +15 dBm for wavelength(s) in range 1260 to 1675 nm
Live Fiber Detection Reports live fiber with input signal ≥ -35 dBm for wavelength(s) in range 1260 to 1675 nm
PON Filter Isolation >50 dB for 1260 nm ≤ wavelength ≤1600 nm
Live PON OTDR Test 1625 or 1650 nm using filtered detector when interfering downstream power in range 1600-1675 nm <-38 dBm
VISUAL FAULT LOCATOR (VFL)
Emitter Type Visible red laser, 650 ±20 nm
Safety Class Class II
Output Power 0.8 mW into single-mode fiber (-1 dBm ±0.5 dB)
Modes CW, 2 Hz flashing
OPTICAL LASER SOURCE – OLS (Optional)
Emitter Type Laser
Safety Class Class I
Fiber Type Single-mode
Wavelengths (nm) N/A 1310/1550 1310/1550 1310/1550 1310/1550
Center Tolerance ±20 nm (CW mode)
Spectral Width (FWHM) 5 nm (maximum)
Internal Modulation 270 Hz, 330 Hz, 1 kHz, 2 kHz, CW, Wave ID
Wave ID Compatible with AFL OPM/OLS
Output Power Stability ≤ ±0.1 dB (15 minutes); ≤ ±0.15 dB (8 hours)
Output Power -3 dBm ±1.5 dB
OPTICAL POWER METER – OPM (Optional)
Calibrated Wavelengths 1310, 1490, 1550, 1625, 1650 nm
Detector Type InGaAs, 1 mm diameter
Measurement Range #ERROR!
Tone Detect Range #ERROR!
Accuracy ±0.25 dB
Resolution 0.01 dB
Measurement Units dB, dBm or Watts (nW, µW, mW)
GENERAL
Size (in boot) 86 x 160 x 43 mm
Weight 0.4 kg
Operational Temperature -10 °C to +50 °C, 0 to 95 % RH (non-condensing)
Storage Temperature -40 °C to +70 °C, 0 to 95 % RH (non-condensing)
Power Rechargeable Li-Pol or AC adapter
Battery Life >12 hours, Telcordia test conditions
Display 4.3 in color touchscreen LCD, 480×272, backlit
USB Ports 1 host; 1 micro-USB function
Bluetooth (optional) Compatible with Windows PC, Android
Wi-Fi Download results & update software via IEEE 802.11 Wi-Fi
Notes: a. All specifications valid at 25 °C unless otherwise specified. b. FDA 21 CFR 1040.10 & 1040.11, IEC 60825-1: 2014. c. Using 10 ns pulse width. d. SNR=1, longest range and pulse width, 3-minute averaging. e. Maximum distance between two points 1.5 dB down each side of a reflective peak caused by an event with reflectance ≤ -45 dB using 3 or 5 ns pulse. f. Maximum distance from the start of a trace spike caused by an event with a -45 dB (or smaller) reflectance, to the point where the trace returns to and stays within ±0.5 dB of backscatter. Test pulse width is 3 or 5 ns. g. Recovery to within 0.5 dB of backscatter after 1:16 splitter (≤13 dB loss) using 50 ns pulse width.
  • FleXpress® mode completes OTDR tests in <5 seconds
  • Test up to 1:64 PON with 25 m PON dead zone
  • Easy to understand LinkMap® results with pass/fail indications
  • Single, dual or triple wavelength single-mode
  • Single port for in- and out-of-service OTDR tests
  • Integrated source, power meter, VFL (visual fault locator)
  • Integrated MPO Switch control via USB
  • Rugged, lightweight, hand-held for field use
  • Available with field-replaceable Port Saver connector