FlowScout® OLS8 Optical Light Source

AFL’s FlowScout OLS8 optical light source represents the next generation of smart optical light sources. Built on the legacy of AFL/Noyes OLS series optical light sources, the FlowScout OLS8 provides a stable and accurate light source for use in enterprise LAN, data center, PON, and broadband networks.

Intuitive operation:With a simple-to-use color touchscreen interface, fiber technicians can quickly set-up, test, validate, and document installed fiber plant, as well as perform troubleshooting as needed.

Wave ID for reduced test time and errors:In the Wave ID mode, the OLS8 encodes each wavelength with a unique Wave ID code. When used with a Wave ID capable power meter, such as OPM8, the pair can test up to three wavelengths simultaneously reducing test time and eliminating wavelength-setting errors. The light source also offers CW mode (continuous output – no encoding) and supports test Tone generation (270 Hz, 330 Hz, 1 kHz, 2 kHz) to assist in troubleshooting.

Flexible reporting:When used in conjunction with AFL’s FlowScout OPM8 power meter, test results may be transferred to a PC running FlexReports PC software. Illuminate your network and report in real-time using AFL’s FlowScout OLS8!

© All images remain the property of their respective manufacturers and are used with permission.
Optical
Model OLS8-QUAD
(MM Optical Port)
OLS8-QUAD
(SM Optical Port)
OLS8-SM
(Single Port)
OLS8-XGS
(Single Port)
Wavelength 850 ±30 nm 1300 ±20 nm 1310 ±20 nm 1550 ±20 nm 1310 ±20 nm 1550 ±20 nm 1310 ±20 nm 1550 ±20 nm 1490 ±20 nm
Spectral Width 45 nm (typ.) 120 nm (typ.) 5 nm (max)
Emitter Type LED Laser
Safety Class Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
Output Power >-20 dBm, 50 μm multimode -1 dBm, 9 μm single-mode
Output Stability ±0.1 dB over 8 hours (after 5 minutes warm-up) ±0.05 dB over 1 hour (after 15 minutes warm-up)
±0.1 dB over 8 hours (after 15 minutes warm-up)
Tone Output 270 Hz, 330 Hz, 1 kHz, 2 kHz
Wave ID Supports AFL Wave ID
General
Available Adapters SC FC, ST, LC
Power 120/240 VAC input; 5VDC @2A output to USB-C
Battery User replaceable Li-Pol; IEC 62133-2:2017 and UN38.3 certified
Operating Time (typical) (c) 10 hours continuous use
Recharge Time (d) ≤3 hours
Data Interfaces USB-C
Operating Temperature -10 °C to +50 °C, 95% RH (non-condensing)
Storage Temperature -30 °C to +60 °C, 95% RH (non-condensing)
IP Rating IP54
Shock & Vibration Withstands 1 m drop test on all 6 sides
Data Storage Non-volatile memory for field-updateable software and results storage
Display 3.5 in. color backlit LCD; capacitive touchscreen; 320 X 480 pixels
Size (H x W x D) 14.0 x 8.1 x 3.3 cm (5.5 x 3.2 x 1.3 in)
Weight ≤290 g (≤0.65 lb)
Calibration N.I.S.T. traceable;≥ 3 years between required re-calibration
Warranty 5 years
Notes:
a. All specifications valid at 25°C unless otherwise specified.
b. All OLS models are equipped with SC/UPC port as standard.
c. Operating conditions: 60 tests in 20 minutes, then auto-off; repeat each hour. Display backlight at minimum brightness.
d. Charging time data is provided for USB-C 2A charger supported Power Delivery 3.0.

Features

  • Large color touchscreen with icon-driven user interface
  • Rugged, dependable, and backed by industry-best 5-year warranty
  • Wave ID generation for reduced test time and user errors
  • Field-replaceable connector adapters for maximum flexibility
  • AFL’s FlexReporter™Test Results Manager integration (via OPM8)

 

Applications

  • Enterprise LAN and Data Center fiber networks
  • FTTH PON networks
  • High power broadband and DWDM systems testing
  • Multimode and single-mode fiber networks